insulation piercing clamp
sample installation
small contract resistance and low temperature rising.
high surability.
wide application range
Applicable voltage: 1KV
Main line(mm2): 95-240
Branch Line(mm2): 95-240
Nominal current: 476A
Dimension(mm):A89*B85.5*H113
Bolt number(pcs):2
Feature
1.insulation piercing connectors is mainly used for branching connection of insulated cable for architectural distribution system,connection of overhead insulated cable, LV insulated service-entrance cable,distributionsystemof streetlight etc.
2.simple installation.the insulated layer of lead needn't be stripped.put the mainline and branch line into connector correctly and screw the moment nut off with a box spanner.
3.small contact resistance and low temperature rise of the clamp.the specially-made moment bolt guarantees constant piercing pressure which enable the connector to get a good electric contract without any excessive conductor damage, and guarantee the normal performance life of circuitry.
4.sealed stunture and high surability. the internal adopts whole sealing structure and is filled with insulating heat conducting grease, which improves insulating strength and security.
5. wide application range. it is applicable to branch connection of copper and aluminum conductor, hetero-dia metric conductor, and butt joint of isodiametric conductor. it is also applicable to transition branch connection of copper and aluminum insulated lead.
Application:
1. installing and fixing main cable in traditional way
2. stripping outer insulator of main cable for 0.6m at part that need part(don't destroy insulation layer for phase).
3. choosing branch cable(not more than3m) whose distance is the same as electric meter box, and strip insulator at two terminals.
4. installing the separator vertically by turns (the sepatator distance is more than 10cm)
Typical application:
1. special for street lamp system(vertical shaft forbidden)
2. for connecting the building lights, street lamp, high building vertical shaft.
3. for connecting the cables of high building vertical shaft, outdoors overhead wire, cable trench, factory power cable.